-40%

Altronix R615DC616UL CCTV Rack Power Supply 6-15VDC @ 6 Amp, 16 Fused Outputs

$ 158.38

Availability: 100 in stock
  • Brand: Altronix
  • Restocking Fee: No
  • Type: Power Distribution Box
  • All returns accepted: Returns Accepted
  • Item must be returned within: 30 Days
  • Return shipping will be paid by: Buyer
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Condition: This looks to be new but I'm listing them as USED.
  • MPN: R615DC616UL
  • Power: 6 Amp
  • Model: R615DC616UL

    Description

    Up For Your Consideration
    1-Altronix R615DC616UL CCTV Power Supply 6-15VDC @ 6 Amp, 16 Fused Outputs
    Lifetime Warranty / Made in the U.S.A
    Description
    Altronix R615DCUL Series Rack Mount CCTV Power Supplies provide 6-15VDC distributed via eight (8) or sixteen (16) fuse or PTC protected outputs for powering CCTV cameras, heaters, and other video accessories.
    Input
    115VAC, 50/60Hz, 1.5A.
    Output
    Sixteen (16) fuse protected outputs.
    6-15VDC @ 6A total output current. (0.375A per device, 3.5A max.)
    Outputs are rated @ 3.5A.
    Filtered and electronically regulated outputs.
    Short circuit and thermal overload protection.
    Electrical
    Temperature:
    Operating: 0° C to 49° C (32° F to 120° F).
    Storage: - 20° C to 70° C ( - 4° F to 158° F).
    Relative Humidity 85% +/- 5%.
    BTU/Hr (approx.): 18-46 BTU/Hr.
    System AC input VA requirement: 172.5VA.
    Features
    Sixteen (16) power LEDs.
    Illuminated master power disconnect circuit breaker with manual reset.
    3-wire grounded line cord.
    Removable terminal blocks with locking screw flange.
    Spare fuses provided.
    Enclosure:
    Modular 2U standard EIA 19" rack mount chassis.
    Dimensions
    19.12"W
    x
    3.25"H
    x
    8.5"D
    (486 mm W x 83 mm H x 216 mm D).
    Allow 1/2U space on top and bottom of the unit for ventilatio
    n.
    Weights (approximate):
    Product Weight:
    17.15 Lbs.
    (7.78 kg).
    Shipping Weight:
    18.15 Lbs.
    (8.23 kg)
    Installation Instructions:
    1. Unit is factory set at 12VDC. To adjust the output voltage remove the top cover to access trimpot on the power supply board (Fig. 1b, pg. 3).
    2. Mount unit in the desired rack location (Space unit at least 3” from any video monitors).
    3. Set power switch on the back of the unit to the OFF position (Fig. 1e, pg. 3).
    4. Plug the power cord into a grounded 115VAC 50/60 Hz receptacle (Fig. 1d, pg. 3).
    5. Set power switch to the ON (RESET) position and measure output voltage before connecting devices (Fig. 1e, pg. 3). This helps avoiding potential damage. CAUTION: Determine the maximum operating voltage of the equipment being powered before adjusting the output voltage.
    6. Set power switch on the back of the unit to the OFF position (Fig. 1e, pg. 3).
    7. Connect devices to the removable terminal blocks marked [1P & 1N] through [8P & 8N] or [1P & 1N] through [16P & 16N], where applicable (Fig. 1c, pg. 3). When wiring is completed on the terminal blocks, they can be locked down by tightening screw flanges. All terminals with common suffix (P) “1P, 2P...” are the same polarity (positive). All terminals with common suffix (N) “1N, 2N...” are the same polarity (negative).
    8. Upon completion of the wiring, set power switch on the back of the unit to the ON (RESET) position (Fig. 1e, pg. 3).
    9. Green power LEDs on faceplate will illuminate when DC output power is present. When an output is in a trouble condition (blown fuse or tripped PTC), the corresponding LED will not be illuminated (Fig. 1, pg. 3).
    a. Blown fuse (R615DC416UL, R615DC616UL, and R615DC8UL) - Set power switch on the back of unit to the OFF position     (Fig. 1e, pg. 3). Remove front faceplate to access fuses. Replace with fuses rated @ 3.5A/250VA (Altronix model # Fuse1).
    b. Tripped PTC (R615DC416ULCB, R615DC616ULCB, and R615DC8ULCB) - To reset PTC, set power switch on the back of   the unit to the OFF position (remove overloaded circuit condition prior to reset). After approximately 30 secs. set power switch to   the ON (RESET) position (Fig. 1e, pg. 3).
    10. Power switch with built-in circuit breaker:
    OFF position - Switch not illuminated. Outputs not powered.
    ON (RESET) position - Switch illuminated.
    Outputs powered. Circuit breaker tripped - Switch not illuminated.
    Power LEDs on faceplate are not illumina
    Outputs not powered. To reset circuit breaker set power switch to the ON (RESET) position (Fig. 1e, pg. 3)
    WARNING: To reduce the risk of fire or electric shock, do not expose the unit to rain or moisture. This installation should be made by qualified service personnel and should conform to the National Electrical Code and all local codes.
    CAUTION: Equipment to be installed / serviced by authorized / trained personnel only. Shut branch circuit power before installing / servicing equipment.
    ed.
    Will be shipped in it's original box
    Please check out my other auctions for more Professional
    Audio, Video & Stage Lighting Equipment From Around Central Florida.
    Thanks For Looking!
    Track Page Views With
    Auctiva's FREE Counter